Item | Date | ||
Output voltage | 0-900V continue adjust | ||
Maximum output average current | 50A | ||
Pulse peak current | 100A | ||
Pulse frequency | 1000Hz | ||
Furnace Working Volume | φ700*1000mm | ||
Rated load | 600KG | ||
Working temperature | ≤650ºC | ||
Ultimate vacuum degree | ≤6.67Pa | ||
Pressure Rise Rate | ≤0.133Pa/min | ||
Vacuum to 20Pa time | ≤30min | ||
Arc extinguishing time | ≤15μs | ||
Temperature Control accuracy | ±1ºC | ||
Pressure Control accuracy | ±1Pa | ||
Process | Automatic control | ||
Equipment lifting | effecive stroke 1000mm |