Customization: | Available |
---|---|
After-sales Service: | on Line and at Site |
Power Supply: | as Customer Request |
Still deciding? Get samples of US$ 25000/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Water content in the box under standard conditions (Note: The standard is one atmospheric pressure and a constant temperature of 20 degrees) |
≤1ppm |
Oxygen content in the box under standard conditions (Note: The standard is one atmospheric pressure and a constant temperature of 20 degrees) |
≤1ppm |
The vacuum value that the transition chamber can withstand | <100pa |
Leakage rate | ≤0.05vo1%/h |
The pressure inside the box | -2500pa.~+2500pa |
Model | Chamber size(mm) | Glove box dimension(mm) |
Glove port | Number of operating surfaces | Glove box |
Remark |
Lab750S-2 |
1220*750*900 |
1915*830*1830 |
¢200 | Single |
2 | Stainless steel vacuum glove box with water and oxygen analyzer,it's less than 1ppm,with purify system. |
Lab750S-3 | 1500*750*900 | 2215*830*1830 | ¢200 | Single |
3 | |
Lab750S-4 | 2440*750*900 | 3215*1060*1830 |
¢200 | Single | 4 | |
Lab1100D-4 | 1220*1100*900 | 1915*1060*1830 | ¢200 | Double | 4 | |
Lab1100D-6 | 1500*1100*900 | 2215*1160*1830 | ¢200 | Double | 6 | |
Lab1100D-8 | 2440*1100*900 | 3215*1060*1830 | ¢200 | Double | 8 |
How the glove box works:
The box and the gas purification system form a closed working environment.
Nitrogen or other inert gases are filled into the box, and the active substances in it are cycled away, so that the system maintains a highly clean and high-purity inert
gas environment(water, oxygen can reach less than 1ppm equipment).
Mainly for the removal of O2 and H2O.
The functions of the glove box system
Name | Introduction |
Box manual/automatic gas replacement | Before using the box for the first time, the air in the box must be 'replaced' with inert gas or ammonia. This can be easily achieved using the automatic gas replacement function of the box provided by the system, or gas replacement can be performed manually. |
Transition chamber box manual/automatic gas replacement | Gas replacement is required for the transition chamber when materials enter the box. This can be easily achieved using the automatic gas replacement function of the transition cabin provided by the system, or gas replacement can be performed manually. |
Gas purification control | After setting the working state and results, the system purification can be set to automatic. The system will automatically control the atmosphere conditions inside the holding box to maintain gas purification. This way, the system can complete the work for us in unmanned situations, or manual control can be selected. |
Foot operated air pressure control |
Foot-operated air pressure control uses a foot-operated controller to control the gas pressure of the box through the system's inflating or pumping. |
Reduction of purification | The reduction of purification materials is automatically completed by the |
system | system, and we only need to provide the system with reduction conditions. After turning on the reduction of the purification system, the system can automatically complete the reduction work for us without the need for personnel monitoring. |
Online working condition detection | The control system provides users with high functionality for detecting the working conditions of equipment components. You can use this function to monitor the working conditions of components online and detect the source of faults for each function and component. |
System parameter settings |
There is a system setting function, and users can achieve the desired working conditions and functional system parameter settings by setting system parameters. |
Data logging function | The system provides a record of device delay parameters, through which we can track or monitor production or experiments. |
Control gas storage function |
When the control gas source is temporarily cut off or insufficient for a period of time, the stored control gas will ensure the continuous operation of the control gas storage function equipment. |
Automatic control | The program control unit realizes automatic control and detection of equipment operation. |
Multi-level security system |
The control system is equipped with multi-level safety reminders, alarms, and prohibition functions. The safety of packaging operators and equipment in a multi-level safety system. |
Purification cycle obstruction protection system |
This function can also detect problems such as blocked system circulation, blocked pipes, and dust collection in filters. |
Optional features for glove box systems |
Data recording and printing, remote service function, system temperature control function. |
Configuration and quantity |
Technical Parameters | Remarks |
1 standard transition box |
DN385*588mm | Located on the right side of the box, material: 304 stainless steel; Aluminum alloy door cover. movable drawers inside; Configure door opening assistance device |
1 tool transition box | DN150*350mm | Located on the right side of the box, Material: 304 stainless steel |
1 piece of storage rack | Double layer | Back-mounted |
1 piece of cabinet rack | Height 900mm | Universal wheel, easy to move the glove box; The purification system is integrated inside the frame in the right segment |
Transparent visible panel |
Thickness: 12mm | Made of double-layer laminated tempered glass |
Gloves | Thickness: 0.4mm | Butyl synthetic rubber |
1 power socket | 220v , 10A | Located inside the glove box, it provides power to the electrical appliances inside the box |
3 sets of spare interfaces |
KF40 | Device for gas or liquid access to the box, made of SU304 stainless steel; equipped with quick connectors |
2 HEPA filters | Transition accuracy: 0.3um |
Installed in the box, it is mainly used to filter dust in the box and protect the ventilation pipes from being unobstructed. |
2 vacuum gauges | Mechanical dial display | Measuring the vacuum of transition chambers and tool transition chamber |
1 pressure gauge | Mechanical dial display | Measure the air pressure of the box |
1 foot pedal controller |
Double pedal type | Gas replenishment and evacuation of control box |
Control System | Color touch screen: 7 inches | Touch screen, PLC brand, SIEMEMS touch screen is hung on the box and can rotate freely. Chinese, English and Russian operating interfaces can be freely switched |
1 pressure sensor | -2500 ~2500pa (relative pressure) | Touch screen display |
1 water analyzer | 0~1000ppm | Touch screen display, accuracy: 0.1ppm, brand: British MICHELL |
1 oxygen transmitter |
0~1000ppm | Touch screen display, accuracy: 0.1ppm, brand: American AII |
Organic solvent adsorption system |
21L | Installed on the glove box pipeline, it is used to absorb solvent gas generated during use and protect the purification materials in the system. |
Our Warehouse:
Q How to select the suitable model and chamber?
A It can be according to your test sample size,if the test sample need a tank,then the better select big chamber.
Q Does your glove box can be customized thickness and valve etc?
A we can according to customer request customized the acrylic thickness,and also can according to customer requirements to make holes,valves etc.
Q Do you have MOQ request?
A MOQ is 1 piece. You can buy one piece as sample.
Q What are the payment terms?
A You can pay through T/T, credit card, Western Union, MasterCard, PayPal, etc.
Q What's your warranty?
A One-year warranty period is provided. Some accessories we have 12-18 months warranty.
Q What's the delivery time?
A We have lots of regular Models in stock. Most of our delivery time would be 3-7 days after we get the payment