Customization: | Available |
---|---|
Type: | Efficient Thickener |
Motor Type: | AC Motor |
Still deciding? Get samples of US$ 5315/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
The ZLS series vacuum centrifugal concentrator has the function of quickly and safely evaporating the water and organic solvents in the sample. The treated samples can be conveniently used for various qualitative and quantitative analytical chemistry, biochemistry, biological analysis, immune screening, food safety, residue analysis, etc. It is suitable for concentration of immunoglobulins, concentration of drug metabolites, SPE solid phase extraction, liquid chromatography and post-treatment, ADMET/toxicology, polymer chemistry, DNA/RNA purification concentration, oligosynthesis, forensic medicine/drug abuse testing, general laboratory concentration.
1.The new XIUI3.0 operating system adopts microcomputer control, programmable operation, direct drive of DC frequency conversion brushless motor, and accurate speed control.
2.7-inch wide viewing angle LCD touch screen, digital input, simple operation, interface real-time display setting and operating parameters and cavity pressure (mBar); all-steel shell, surface corrosion-resistant orange peel fine wrinkle treatment, full lines, industrial human-machine overall design based on visual beauty while giving it a sense of security, recognition rate High.
3.One-button preheating: adopt accurate temperature control technology, fast heating, high temperature control accuracy, can heat the temperature in the cavity to 60ºC, quickly reach the set temperature and keep the temperature unchanged. ( Applicable to ZLS-1/ZLS-2/ZLS-3)
4.One-click pre-cooling: imported fluorine-free refrigeration compressor set (refrigerant R404a) is adopted, which meets the requirements of environmental protection, with pre-cooling function and a wide temperature control range: -20ºC to +60ºC, which can quickly reach the set temperature; the national standard copper tube is embedded in the cavity, with strong cold and heat exchange capacity, ensuring the constant temperature centrifugal effect. ( Applicable to ZLS-4/ZLS-6)
5. Vacuum degree setting: When the rotational speed reaches the set value, the vacuum can be started.
6.During operation, the vacuum degree can be controlled in the setting accuracy, the sublimation efficiency can be improved, and the safe and efficient concentration of no pollution, foam and non-destructive samples.
7.Automatic vacuum unloading: When the instrument is finished or the power outage/down state, the vacuum state will be automatically removed and ventilated with the external environment, which will be slowly released to protect the sample from excessive positive and negative pressure. After complete release, the instrument will automatically open the cover.
8.The built-in organic solvent vapor pressure curve shows the vapor pressure data of different organic solvents at different temperatures in detail to help users understand the evaporation characteristics of organic solvents. Avoid misoperation or safety accidents caused by not knowing the characteristics of the solvent.
9.304 stainless steel seamless molding centrifugal cavity, corrosion-resistant treatment without fear of sample solvent, and can also ensure the purity of sample solvent.
10.A variety of rotors meet the needs of different experimental fluxes, and can carry out pre-treatment centrifugation and concentration of nucleic acid, viruses and other samples.
11.Split design: independent accessories, free matching, flexible use.
Product name | ZLS-1 | ZLS-2 | ZLS-3 | ZLS-4 | ZLS-6 | |||||
Max Speed | 1500r/min | 2000r/min | 2000r/min | |||||||
Max Power | 1kW | 2.4kW | 2.5kW | 0.5kW | 3.5kW | |||||
Max Current | 5A | 11A | 11A | 2.5A | 11A | |||||
Ambient Temp | 0ºC~+35ºC | |||||||||
Temp.control Range | Room Temp~+60ºC | Room Temp~+60ºC(+70ºC,+80ºC) | -20ºC~+40ºC | -20ºC~+80ºC | ||||||
Timer range | 1min-23h59min59s | |||||||||
On/off switch | Manual | Automatic | Manual | Automatic | ||||||
Pre-heat function | Yes | No(pre-cool function) | ||||||||
One-click linkage | No | Yes | ||||||||
Final Vacuum | 0.1mbar | |||||||||
Auto leakage | No | Yes | Yes | |||||||
Vacuum degree | No | Yes | No | Yes | ||||||
display | ||||||||||
Vacuum connector | Φ10mm | |||||||||
Vacuum pump (optional) |
Domestic diaphragm pump/oil pump, imported oil pump/diaphragm pump | |||||||||
Cool trap(optional) | CT-6/ CT-40/ CT-50 | |||||||||
Noise | ≤50dB(A) | ≤60dB(A) | ||||||||
Power | AC220V/50Hz | |||||||||
Weight | 21kg | 42kg | 55kg | 70kg | 90kg | |||||
Dimension(L*W*H) | 500×460×280 | 400×540×350 | 480×600×410 | 710×630×380 | 490×660×380 |
Changsha Samy Instrument and Equipment Co., Ltd. is a high-tech enterprise with powder equipment as its core products, integrating product research and development, production and sales. Its main products include ball mills, crushers, mixing equipment, etc. Our company has passed ISO9001 and CE product certification.Our planetary ball mill is the necessary device for mixing,find grinding,small sample preparation,new product development and small batch production.Planetary ball mill machine widely used in geology,minerals,metallurgy,electronics,building materials,ceramics,chemical industry,environmental proetection and others departments,and has now become a well-known brand in the country.
Our Office:
1.Q: What type of Centrifugal Concentrator do you have?
A: There are ZLS-1,ZLS-2,ZLS-3,ZLS-4,ZLS-6.
2. Q: What is the function of your Centrifugal Concentrator?
A: The ZLS series vacuum centrifugal concentrator has the function of quickly and safely evaporating the water and
organic solvents in the sample.